AutoGas 5 Gas Analyser

AutoGas 5 Gas Analyser

The Portable Five Gas Analyser can be used as a stand-alone unit or integrated into a Vehicle Test Lane.

  • Capability to measure CO, HC, CO2, O2 and NOX contents of petrol, CNG, and LPG vehicle exhausts.
  • RPM measurement facility using vehicle battery, inductive pick-up, or optional accelerometer.
  • Compatible with Windows-based operation
  • Complies with the OIML R99 (ISO 3930) Class 0
  • Portable, light-weight design.

Standard Accessories:

  • Sampling probe assembly for gas intake
  • Battery cable assembly
  • Oil temperature probe.
  • Inductive Pick-up

Optional Accessories:

  • Accelerometer sensor pick-up
  • Gas test software for Windows.

Calibration:

  • 12-month intervals.

Technology:

  • Measurement of CO, CO2, O2, and HC and NOX
  • Operates on 220V AC inputs or 12V- 30V DC.
  • Complies with OIML R99 (ISO 3930) Class 0.

Specifications

General
• Power: Designed to be powered either in 13.5 VDC,110VAC and 230 VAC
• Continuous voltage power supply (DC):
• Operating range: 13.5 VDC ±15%
• Required power: 65 W
• Alternating voltage (AC):
• Operating range: 110-230 VAC +10% -15%
• Frequency: 50-60 Hz ±2%
• Effective optical length: 215mm +/-0.5mm
• Tube Preheating time: 3 to 6 min depending on ambient temperature
• Resolution: 0.1% or 0.01 m-1
• Accuracy: < 1.0% of opacity in the full range
• Ambient temperature range for operation: +2 to+40°C
• Humidity: 30% to 90%
• Storage temperature: -32°C to +55°C
• Measured gas Temperature: 0-256 C +/- 1
• Light Source: (LED) spectral peak 560nm ±10nm
• Light Detector: peak spectral response 560nm ±10nm
• N value: Scale range from 0.00 to 99.9%
• K value: Scale range from 000 to 9.99 m-1
• Physical response time: < 0.2 sec (10% to 90%)
• Electrical response time: 0.9 sec
• Size: 200 mm x 400 mm x 170 mm
• Weight: 9kg
• Battery operated – built in, rechargable
• Automatic Zero adjustment and calibration before use
• Automatic adjustment for sooting
• Suitable for diesel engines
• Auto-sleep feature
• Weekly calibration check
• WiFi connected
• PC software controlled

AutoGas User Manual
AutoTest FAQ AutoGas
AutoSmoke Opacity Meter User Manual
AutoSmoke Opacity Meter Brochure

Specifications

General
• Power: Designed to be powered either in 13.5 VDC,110VAC and 230 VAC
• Continuous voltage power supply (DC):
• Operating range: 13.5 VDC ±15%
• Required power: 65 W
• Alternating voltage (AC):
• Operating range: 110-230 VAC +10% -15%
• Frequency: 50-60 Hz ±2%
• Effective optical length: 215mm +/-0.5mm
• Tube Preheating time: 3 to 6 min depending on ambient temperature
• Resolution: 0.1% or 0.01 m-1
• Accuracy: < 1.0% of opacity in the full range
• Ambient temperature range for operation: +2 to+40°C
• Humidity: 30% to 90%
• Storage temperature: -32°C to +55°C
• Measured gas Temperature: 0-256 C +/- 1
• Light Source: (LED) spectral peak 560nm ±10nm
• Light Detector: peak spectral response 560nm ±10nm
• N value: Scale range from 0.00 to 99.9%
• K value: Scale range from 000 to 9.99 m-1
• Physical response time: < 0.2 sec (10% to 90%)
• Electrical response time: 0.9 sec
• Size: 200 mm x 400 mm x 170 mm
• Weight: 9kg
• Battery operated – built in, rechargable
• Automatic Zero adjustment and calibration before use
• Automatic adjustment for sooting
• Suitable for diesel engines
• Auto-sleep feature
• Weekly calibration check
• WiFi connected
• PC software controlled

AutoGas User Manual
AutoTest FAQ AutoGas
AutoSmoke Opacity Meter User Manual
AutoSmoke Opacity Meter Brochure

Our History

From humble beginnings in 1983 we have been working with governments in many areas of vehicle safety.

Our History

From humble beginnings in 1983 we have been working with governments in many areas of vehicle safety.

Stay ahead
with AutoTest!

Keep your workshop and equipment updated!
Subscribe to our newsletter for exclusive sales, discounts, and the latest news.

Sign up today!