Search

AutoBlast Ground Vibration Logger

AutoBlast Ground Vibration Logger

AutoBlast is a ground vibration monitoring and logging device. It can be used  in various applications of Civil Engineering such as industrial vibration monitoring,  ground transportation traffic vibration monitoring, construction site monitoring,  noise, and vibration monitoring in a blasting zone. It is also useful in the fields of  Earthquake Engineering for monitoring the structures of buildings, bridges, and  dams.

Measurement is taken using a packet of velocity sensors (geophones) and Air  Overpressure level using a microphone, storing the data into a built-in memory  storage, which can be downloaded to a PC via Bluetooth. AutoBlast can be configured to perform a sensor check operation before monitoring starts to make  sure, the sensors are functioning properly. Events are automatically recorded when the measurement level of the vibration  noise exceeds a threshold value, and alarms can be raised. These can be auxiliary alarms (i.e., light signal or siren) as well as notifications sent by Email or SMS using the built-in modem.

Self Contained http connected(4G)

Vibration Range Up to 250 mm/s
Resolution 0.0077 mm/s
Accuracy ± 5% or ±0.5 mm/s
Frequency range 1 to 180 Hz
Acceleration Calculated from captured waveform
Trigger levels 0.13 to 250 mm/s
Air Overpressure Monitoring Weighting scales ISEE Linear
Range 88 to 145 dB (500 Pa peak)
Resolution 0.0152 Pa
Frequency Response 2 to 250 Hz
Accuracy ± 10% or ± 1dB
Trigger level 100 to 145 dB in steps of 0.1dB
Sampling rate 50, 100, 200, 400, 500, 800, 1000, 1600,2000 samples/sec for each channel
Real-time Clock (RTC) Built-in clock with backup battery
Storage space Full waveform recording 400 events
(At 1000 Hz, 1.25 sec length, 4 channels)
Histogram recording 21 days (at 5 sec interval) for 4 channels; 30 days (at 7 sec interval)
270 days (at 1 min interval)
Full waveform and histogram 30 days (at 1 min interval); 400 events (at 1000 Hz, 1 sec length)
(Mix Mode)
Modem LTE (Bands: 1, 3, 5, 7, 8, 28); UMTS/DC-HSPA+ (850/900/1900/2100) GSM/Edge (850/900/1800/1900)
Bluetooth Bluetooth Class 2 with embedded antenna
PC Connectivity via Bluetooth Bluetooth class 2 (range: 3 m)
Serial (RS232) Serial port connection
GPRS (Internet) TCP/IP (Internet)
FFT Analysis via PC software, Australian 2187.2-1993 Standard
User interface 1×16 character LCD with backlight
Alarm notification Alarm messages via email, SMS and external relay outputs
Auxiliary Relay Output 2 Auxiliary relay outputs 12V 1A (12W)
Battery Capacity Internal 6V 7000 mAh
Dimensions (w x h x d) 180 x 110 x 45 mm
Operating temperature -10℃ to +70℃
Humidity Up to 90% non-condensing
Supply Voltage 10 – 14 V
Power consumption 50 mA (Standby); 100 mA (Typical)
Warranty 12 months

Blast and Piling Vibration

Product Downloads

Click here for product manuals and brochures.

AutoBlast Ground Vibration Logger Manual
AutoBlast Ground Vibration Logger Brochure

Self Contained http connected(4G)

Vibration Range Up to 250 mm/s
Resolution 0.0077 mm/s
Accuracy ± 5% or ±0.5 mm/s
Frequency range 1 to 180 Hz
Acceleration Calculated from captured waveform
Trigger levels 0.13 to 250 mm/s
Air Overpressure Monitoring Weighting scales ISEE Linear
Range 88 to 145 dB (500 Pa peak)
Resolution 0.0152 Pa
Frequency Response 2 to 250 Hz
Accuracy ± 10% or ± 1dB
Trigger level 100 to 145 dB in steps of 0.1dB
Sampling rate 50, 100, 200, 400, 500, 800, 1000, 1600,2000 samples/sec for each channel
Real-time Clock (RTC) Built-in clock with backup battery
Storage space Full waveform recording 400 events
(At 1000 Hz, 1.25 sec length, 4 channels)
Histogram recording 21 days (at 5 sec interval) for 4 channels; 30 days (at 7 sec interval)
270 days (at 1 min interval)
Full waveform and histogram 30 days (at 1 min interval); 400 events (at 1000 Hz, 1 sec length)
(Mix Mode)
Modem LTE (Bands: 1, 3, 5, 7, 8, 28); UMTS/DC-HSPA+ (850/900/1900/2100) GSM/Edge (850/900/1800/1900)
Bluetooth Bluetooth Class 2 with embedded antenna
PC Connectivity via Bluetooth Bluetooth class 2 (range: 3 m)
Serial (RS232) Serial port connection
GPRS (Internet) TCP/IP (Internet)
FFT Analysis via PC software, Australian 2187.2-1993 Standard
User interface 1×16 character LCD with backlight
Alarm notification Alarm messages via email, SMS and external relay outputs
Auxiliary Relay Output 2 Auxiliary relay outputs 12V 1A (12W)
Battery Capacity Internal 6V 7000 mAh
Dimensions (w x h x d) 180 x 110 x 45 mm
Operating temperature -10℃ to +70℃
Humidity Up to 90% non-condensing
Supply Voltage 10 – 14 V
Power consumption 50 mA (Standby); 100 mA (Typical)
Warranty 12 months

Blast and Piling Vibration

Product Downloads

Click here for product manuals and brochures.

AutoBlast Ground Vibration Logger Manual
AutoBlast Ground Vibration Logger Brochure

Related Products

View these related products and get the most out of the AutoTest range.

Our History

From humble beginnings in 1983 we have been working with governments in many areas of vehicle safety.

Our History

From humble beginnings in 1983 we have been working with governments in many areas of vehicle safety.